  Datasheet File OCR Text:
 Broadband Surface Mount Mixer
SME1400B-13
The Communications Edge TM
Product Features * RF 1 to 2200 MHz * LO 1 to 2200 MHz * IF 1 to 2000 MHz * LO Drive: +13 dBm (Other Levels Available) * No Internal Solder Connections
Product Photo
Specifications
Parameter SSB Conversion Loss (Max) RF/LO = 10-1300 MHz, IF = 10-1000 MHz RF/LO = 10-2500 MHz, IF = 30-1000 MHz RF/LO = 1-2200 MHz, IF = 1-2000 MHz Port-to-Port Isolation (Min) L-R = 10-2000 MHz L-R = 10-2500 MHz L-I = 10-2000 MHz L-I = 10-2500 MHz R-I = 10-2200 MHz 3rd Order Input Intercept Point VSWR R-Port = 600-2000 MHz R-Port = 10-2500 MHz L-Port = 600-2000 MHz L-Port = 10-2500 MHz I-Port 1 dB Conversion Compression Units dB dB dB dB dB dB dB dB dBm Typical 6.5 7.5 8.0 30 25 26 22 25 22 1.7:1 2.0:1 1.6:1 2.0:1 1.8:1 +9 Guaranteed +25C -40 to +85C 8.0 9.0 8.5 9.5
21 17 20 16
dBm
1. Measured in a 50-ohm system with nominal LO drive of +13 dBm, low side LO, and downconverter application only, unless otherwise specified. 2. Measured at RF = 820 MHz, LO = 750 MHz, IF = 70 MHz, unless otherwise specified.
Absolute Maximum Ratings
Parameter Operating Temperature Storage Temperature Combined RF and LO Input Power Rating -40 to +85C -65 to +100C +19 dBm
Ordering Information
Part No. Description SME1400B-13 Mixer (Available in tape and reel) SME1400B-13-PCB Fully Assembled Application Circuit
WJ Communications, Inc. * Phone: 1-800-WJ1-4401 * FAX: 408-577-6621 * e-mail: sales@wj.com * Web site: www.wj.com
June 2002
SME1400B-13
Performance Charts
Conversion Loss vs. Frequency
5 6 Conversion Loss (dB) Conversion Loss (dB) 7 8 9 10 11 12 8.0 0 500 1000 1500 2000 2500 Frequency (MHz) 6 8 10 12 14 16
IF = 2000 MHz IF = 100 MHz
Conversion Loss vs. RF Power
6.0 6.0 6.2 Conversion Loss (dB) 6.4 6.6 6.8 7.0 10
Conversion Loss vs. LO Power
6.5
7.0
RF = 900 MHz
7.5
LO = 800 MHz
RF = 1500 MHz IF = 500 MHz LO = 1000 MHz
11
12
13 LO Power (dBm)
14
15
16
RF Power (dBm)
Conversion Loss vs. Temperature
6.5 6.7 Conversion Loss (dB) Intercept Point (dBm) 6.9 7.1 7.3 7.5 -40 30
IIP3 vs. Frequency
22
IF = 300 MHz
IIP3 vs. LO Power
25 20 15 10 5 -20 0 20 Temperature (C) 40 60 80 0 500 750 1000 1250 1500 1750 2000 2250 18 10 11 12 13 LO Power (dBm) Intercept Point (dBm) 21
IF = 100 MHz
20
RF = 2000 Mhz LO = 1900 MHz IF = 100 MHz
19
14
15
16
RF Frequency (MHz)
VSWR vs. Frequency
2.6 50 45 2.2
LO
Isolation vs. Frequency
L-R
Isolation (dB)
RF
40 35 30 25 20
L-I L-I
VSWR
1.8
1.4
IF, LO = 1260 MHz
1.0 0 500 1000 1500 2000 2500 Frequency (MHz)
0
500
1000
1500
2000
2500
Frequency (MHz)
WJ Communications, Inc. * Phone: 1-800-WJ1-4401 * FAX: 408-577-6621 * e-mail: sales@wj.com * Web site: www.wj.com
June 2002
SME1400B-13
Single-Tone IM Products
Harmonics of fLO 0 Harmonics of fRF 0 1 2 3 4 5 LO Mult 0 0 0 0 0 1 -1 -1 -1 -1 -1 2 -2 -2 -2 -2 -2 3 -3 -3 -3 -3 -3 4 -4 -4 -4 -4 -4 5 -5 -5 -5 -5 -5 17 64 >80 >80 >80 RF Mult 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 1 22 0 60 77 >80 >80 LO MHz 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2 27 19 61 >80 >80 >80 3 28 23 60 78 >80 >80 RF MHz 2200 2200 2200 2200 2200 2200 2200 1100 734 550 440 2200 4350 2175 1450 1088 870 2200 6500 3250 2167 1625 1300 2200 8650 4325 2884 2163 1730 2200 10800 5400 3600 2700 2160 4 39 39 65 >80 >80 >80 IM Prod MHz 2200 4400 6600 8800 11000 2150 50 50 52 50 50 4300 50 50 50 52 50 6450 50 50 51 50 50 8600 50 50 52 52 50 10750 50 50 50 50 50 dB 17 64 81 86 86 22 0 60 77 92 89 27 19 61 85 90 88 28 23 60 78 89 88 39 39 65 81 90 87 34 46 73 88 89 89 5 34 46 73 >80 >80 >80
Test Conditions RF at -10 dBm; LO at +13 dBm RF harmonics and intermodulation products are referenced to a desired signal produced by fRF = 2200 MHz and fLO = 2150 MHz. LO harmonics are referenced to the LO drive signal.
WJ Communications, Inc. * Phone: 1-800-WJ1-4401 * FAX: 408-577-6621 * e-mail: sales@wj.com * Web site: www.wj.com
June 2002
SME1400B-13
Outline Drawing
Land Pattern Mounting Configuration
Specifications and information are subject to change without notice.
Caution! ESD sensitive device.
WJ Communications, Inc. * Phone: 1-800-WJ1-4401 * FAX: 408-577-6621 * e-mail: sales@wj.com * Web site: www.wj.com
June 2002


▲Up To Search▲   

 